Get a 50% OFF! when buying 2 or more study guides. SALE ENDS IN: 03:23:20

Network Appliance NS0-521 Exam Questions
NetApp Certified Implementation Engineer - SAN, ONTAP

NS0-521  Exam Dumps Questions and Answers
  • NS0-521 - Certification Exam Questions
  • Questions & Answers (PDF): 111
  • Testing Engine Included
  • Last Update: 15-Sep-2025
  • Free Updates: 60 Days
  • Price (one time ): Buy 1 Get 1 Free $68
  • INSTANT DOWNLOAD

Realistic NS0-521 Practice Exam Simulation Software Included

Xengine Exam Simulation
Intuitive Exam Score Report
Xengine App Demo
Xengine App Demo

Recent NS0-521 Exam Certification Discussions & Feedbacks

Nick

Just bought it, hope for the best
Anonymous


NA

Spot on, good material.
Anonymous


Brian

I checked the free questions at free-briandumps.com then got the full verison from here. This helped me pass my exam.
UNITED STATES


Makvi

hello dears
LIBYAN ARAB JAMAHIRIYA


Dinesh Basappa

It is really good to complete the exams
INDIA


kris

this was very good and informative and helpful. thanks
UNITED STATES


Abdullah

It is the best website
Anonymous


Bio

200-201 CBROPS 092023 - Exam still 75% to 80% valid. Suggest to those who wants to pass to study this, along with netacads, and review quizlets to ensure you pass.
GERMANY


DUNG TRAN

Thank you for your support!
Anonymous


Ranjith

It's great site to get certification.
Anonymous


DK

Great practice questions
Anonymous


Rahol

I passed my Azure exam last week and now preparing for my AWS exam. Just to share my experience... Some exams are divided into sections and models, others are not. The CLF-C01 exam is one of them. Unfortunately, the structure of the AWS exams are totally different from the Microsoft exams.  I suggest you practice using the Xegine App and divide the questions in different phases and study that way. For example, study questions 1 to 100. Once you are comfortable with that you can get a passing score of 90% or more, move on to questions 101 to 200... and so on.I hope this helps.
CANADA


Truffles

Hope this helps me
UNITED STATES


Joe Sander

I have used this company to pass my LPIC-1 exams and have been very pleased with the outcome. Both exams I was able to pass the first time around
UNITED STATES


Liwander

Não esta sendo possível pagar pelo paypal!
Anonymous


Bryan

Big thanks to AllBrainDumps for providing such a great resource, helping me preparing to achieve my goal, saving lots of time!
TAIWAN PROVINCE OF CHINA


DUNG TRAN

It used Engine Test Simulator. After practicing for 14 days I made sure I get 90% or more. Then I did my DEA-5TT2 exam and passed.
Anonymous


AB

200-201 is still good. passed Aug 14
UNITED STATES


DD

Just got CSCP and CPIM together, 2 weeks to exam. Let's pass it!
CANADA


Binod

Feeling excited for preparing exam
Anonymous


Computers Student

I am planning to take this exam soon. I will share the results.
SOUTH AFRICA


Anonymous

Are you allowed to disclose IAPP CIPM real exam question by providing exam dumps?
NETHERLANDS


Louis

works good love the program
UNITED STATES


Doddy

I have passed PT0-002, thanks!
Anonymous


Nalini

By far one of the most acurate set of qeustions. Almost all qustions were in the exam. I passed my test with 97%.
INDIA


Stag9

Surely, have been helpful! an add on layer of confidence before exam.
UNITED STATES


Read more here...

Post your comments and get a 20% discount.

NS0-521 Practice Questions


During an iSCSI deployment, the customer requests a change of front-end network connections on the NetApp ONTAP cluster from twinax cables to fiber-optic cables.
Which two NetApp tools would an administrator use to verify the supported port speeds and transceivers? (Choose two.)

  1. Hardware Universe to determine supported transceivers
  2. Interoperability Matrix Tool to determine supported transceivers
  3. Hardware Universe to determine supported port speeds
  4. Interoperability Matrix Tool to determine supported port speeds

Answer(s): A,B

Explanation:

During an iSCSI deployment, if a customer requests a change from twinax cables to fiber-optic cables, two NetApp tools can be used to verify the supported port speeds and transceivers:
Hardware Universe (HWU): This tool is essential for determining the supported transceivers and port speeds for NetApp hardware. It provides detailed information on hardware compatibility, including supported transceivers, cables, and port speeds, which helps ensure that the selected components are compatible with the NetApp storage system.
Interoperability Matrix Tool (IMT): The IMT provides comprehensive compatibility information between NetApp products and third-party components. It includes details on supported transceivers and port speeds, ensuring that any changes made to the network connections are supported and will function correctly in the given configuration.

For more detailed information, you can refer to the following resources:
NetApp Hardware Universe(NetApp).
NetApp Interoperability Matrix Tool(NetApp).



An administrator has a NetApp AFF cluster with two SVMs serving LUNs. SnapMirror active sync is configured, and a disaster recovery test is planned over the weekend.
Which NetApp ONTAP command will show the status of this test?

  1. snapmirror failover show
  2. network interface failover-groups show
  3. storage failover hwassist show
  4. snapnirror config-replication status show

Answer(s): A

Explanation:

To check the status of a SnapMirror active sync disaster recovery test on a NetApp ONTAP cluster, you would use the command snapmirror failover show. This command provides the necessary details about the failover status, helping administrators verify if the disaster recovery test is proceeding as expected. It displays the status of the failover groups and their readiness, which is essential for confirming the effectiveness of the disaster recovery setup. For more detailed information on SnapMirror commands and their usage, refer to:
NetApp Documentation - SnapMirror Commands(NetApp Community)(NetApp Community).



What configuration must be applied for NVMe/FC?

  1. Create multiple initiator zones and multiple target zones.
  2. Configure igroup and IQN mapping.
  3. Enable NPV on all fabric switches.
  4. Enable NPIV on all fabric switches.

Answer(s): D

Explanation:

When configuring NVMe/FC (NVMe over Fibre Channel), it is necessary to enable N_Port ID Virtualization (NPIV) on all fabric switches. NPIV allows multiple Fibre Channel initiators to share a single physical Fibre Channel port, which is crucial for NVMe/FC environments where efficient utilization of available ports is needed.
NPIV support enables the creation of virtual ports, which can significantly optimize the configuration and management of Fibre Channel fabrics, thus supporting NVMe/FC operations.
For further details, you can refer to:
NetApp Community - NVMe/FC Configuration(NetApp Community).
NetApp Documentation - NVMe Overview(NetApp).



A storage administrator has just completed an ISCSI implementation in a customer environment running VMware and needs to validate that the entire network path supports jumbo frames.
Which action should be taken?

  1. Ping from the host with fragmentation.
  2. Check the VMkernel adapter settings.
  3. Ping from the host without fragmentation.
  4. Check the broadcast domain settings.

Answer(s): A

Explanation:

To validate that the entire network path supports jumbo frames after an iSCSI implementation, you should perform a ping test from the host with fragmentation. This involves using the ping command with specific options to test jumbo frame support:

ping -M do -s 8972 <target_IP>
In this command:
-M do ensures the packets are not fragmented.
-s 8972 sets the packet size to 8972 bytes (9000 bytes MTU minus 28 bytes for the ICMP header). By confirming that the large packets are successfully transmitted without fragmentation, you can validate that the network path, including switches and adapters, supports jumbo frames.
For more details, you can check:
NetApp Documentation - iSCSI Configuration and Best Practices(NetApp)(NetApp).



An administrator installs a new NetApp ONTAP system in a customer's SAN environment. The customer wants to confirm that ALUA correctly changes the path states between Active/Optimized and Active/Nonoptimized.
Which event causes ALUA to change the path states?

  1. Shut down all FC LIFs on the HA partner node.
  2. Move the containing volume to the HA partner node.
  3. Shut down one FC LIF.
  4. Disconnect one FC cable on the node hosting the LUN.

Answer(s): A

Explanation:

ALUA (Asymmetric Logical Unit Access) is a protocol used in SAN environments to manage paths between a host and its storage. It enables the host to recognize and manage paths to the LUNs more efficiently by designating paths as either "Active/Optimized" or "Active/Nonoptimized". A significant event, such as shutting down all FC LIFs on the HA partner node, will trigger ALUA to change the path states. This action effectively causes the storage paths to transition from the HA partner node to the local node, switching the path states from Active/Nonoptimized to Active/Optimized on the paths that remain active.
For more information, you can refer to:
NetApp Community Discussion on ALUA
NetApp Documentation on ALUA



An engineer Is implementing a data migration scenario for a customer who has multiple FC LUNs across multiple third-party SAN arrays. The engineer wants to use Foreign LUN Import (FLI) for the migration.
What is a requirement on the destination NetApp ONTAP cluster for FLI?

  1. A valid SnapMirror license
  2. At least one FC port in initiator mode
  3. A valid NetApp XCP license
  4. At least one FC port in target mode

Answer(s): D

Explanation:

When using Foreign LUN Import (FLI) for migrating LUNs from third-party SAN arrays to a NetApp ONTAP system, one of the requirements is to have at least one Fibre Channel (FC) port configured in target mode on the destination NetApp ONTAP cluster. This configuration is necessary to facilitate the migration process as the target mode port will accept and manage incoming data from the source SAN arrays.
For additional details, refer to:
NetApp Documentation on FLI



What connectivity Is required between NetApp ONTAP clusters in order to configure SnapMirror active sync across two data centers for FC?

  1. Cedicated FC switches and ISL
  2. Shared FC switches
  3. Cluster peering
  4. Dedicated IP switches and ISL

Answer(s): C

Explanation:

To configure SnapMirror active sync across two data centers using FC (Fibre Channel), the required connectivity between NetApp ONTAP clusters is cluster peering. Cluster peering involves establishing a trust relationship between the clusters, allowing them to replicate data seamlessly. This setup ensures that data synchronization and disaster recovery processes are effective and reliable.

For more detailed information, you can check:
NetApp Documentation on SnapMirror and Cluster Peering



What is the minimum number of rack units that are required on each site for a NetApp AFF All San Array (ASA) A800 MetroCluster IP configuration with 72 disks per site and Cisco N9K-C9336C-FX2 backend switches?

  1. 16 RU
  2. 8 RU
  3. 12 RU
  4. 4 RU

Answer(s): A

Explanation:

For a NetApp AFF All SAN Array (ASA) A800 MetroCluster IP configuration with 72 disks per site and Cisco N9K-C9336C-FX2 backend switches, the minimum number of rack units required on each site is 16 RU. This includes space for the controllers, disk shelves, and the necessary network switches. This configuration ensures that all components are properly accommodated and operational within the specified rack space.
For detailed information on the rack unit requirements and MetroCluster IP configurations, refer to:
NetApp Documentation on MetroCluster IP
MetroCluster IP Solution Architecture



What Is modified when moving a LUN between different HA pairs in the same SVM to prevent loss of connectivity?

  1. port name
  2. reporting nodes
    C igroup
  3. LUN mapping

Answer(s): B

Explanation:

When moving a LUN between different HA pairs in the same SVM to prevent loss of connectivity, the reporting nodes must be modified. The reporting nodes configuration ensures that the initiator paths are properly updated to reflect the new physical location of the LUN. This prevents disruptions in connectivity by maintaining the correct pathing information for the host systems accessing the LUN.
For more details, refer to:
NetApp Documentation on LUN Management



A customer has created an SVM for their SAN workloads. They now want to configure the SVM to use NVMe/FC. Which two steps are needed to accomplish this task? (Choose two.)

  1. Add the FC protocol.
  2. Create the FC service.
  3. Create an NVMe/FC LIF.
  4. Create the NVMe service.

Answer(s): A,C

Explanation:

To configure an SVM to use NVMe/FC, the following steps are necessary:
Add the FC protocol: This step involves enabling the Fibre Channel protocol on the SVM, which is required to support NVMe over Fibre Channel.
Create an NVMe/FC LIF: Logical Interfaces (LIFs) must be created to handle NVMe traffic over the Fibre Channel network. These LIFs enable the NVMe namespace access to the host systems. These steps ensure that the SVM is correctly set up to use NVMe/FC, allowing for efficient and high- performance access to NVMe storage.
For more information, refer to:
NetApp NVMe/FC Configuration



A storage administrator wants to increase security and optimize performance in a recently implemented SAN deployment.
What should the storage administrator configure to ensure initiator restriction to certain LIFs?

  1. Subnets
  2. Network route
  3. Broadcast domain.
  4. Access list

Answer(s): D

Explanation:

To increase security and optimize performance in a SAN deployment, configuring an access list is essential. Access lists restrict initiator access to specific LIFs, ensuring that only authorized hosts can connect to the storage system. This helps in enhancing security by preventing unauthorized access and optimizes performance by controlling and managing the paths used for storage access.
For additional details, you can refer to:
NetApp SAN Administration Guide



A LUN Is displaying 90% used space in the NetApp ONTAP CLI, but a Windows Server shows only 10% used space.

What is the first step to take to address this issue?

  1. Enable automatic resizing.
  2. Disable automatic resizing.
  3. Disable space allocation.
  4. Enable space allocation.

Answer(s): D

Explanation:

When a LUN shows 90% used space in the NetApp ONTAP CLI but a Windows Server shows only 10% used space, the discrepancy is often due to how space allocation is handled between the two systems. Enabling space allocation ensures that the ONTAP system accurately reflects the actual space usage as reported by the host system, in this case, the Windows Server. This adjustment allows ONTAP to reclaim and manage space more effectively, aligning the reported usage between the ONTAP system and the host.
For more information, refer to:
NetApp Community Discussion on Space Allocation
NetApp Documentation on Space Usage




Pass Guaranteed!

Quality Assurance for Exam Success!

We assure a 100% money-back guarantee, safeguarding your investment.
Sometimes people fail in their certification exams even if they know the right answers to the questions. This condition is caused by mental block during the exam as students tense up under pressure. Allbraindumps.com prepares you for such situation, making you become more confident during the real exam.

Our meticulously crafted study packages, are tailored to mirror real exam scenarios and labs. With a commendable 90% passing rate, We guarantees a successful first attempt of achieving your certification goal, showcasing our unwavering confidence in the excellence of our study materials.

Money Back Guarantee

Prepare for the NS0-521 NetApp Certified Implementation Engineer - SAN, ONTAP certification exam and pass in first try!

If you are preparing for your NS0-521 certification exam then you have come to the right place. We provide the latest NS0-521 NetApp Certified Implementation Engineer - SAN, ONTAP test questions and Answers which is going to guarantee your pass in first try!

  • Free updates for NS0-521 NetApp Certified Implementation Engineer - SAN, ONTAP Exam Package for 60 DAYS.
  • Unlimited access and download to NS0-521 NetApp Certified Implementation Engineer - SAN, ONTAP practice exam questions and NS0-521 preparation guide from anywhere and to any PC for 60 DAYS.
  • Instant access to download your NS0-521 NetApp Certified Implementation Engineer - SAN, ONTAP Exam material including practice Questions & Answers and the Interactive Software.
  • Fast technical support to answer your questions and inquiries about this NS0-521 study package.
  • 90%+ historical pass rate guaranteed on your NS0-521 NetApp Certified Implementation Engineer - SAN, ONTAP exam or you receive a full refund.
  • 256-bit SSL real time secure purchasing when paying for NS0-521 NetApp Certified Implementation Engineer - SAN, ONTAP study package.

Commonly Asked Questions About Network Appliance NS0-521 Study Package:

  • What is the content of this Network Appliance NS0-521 Study Package?

    This Network Appliance NS0-521 preparation exam contains latest practice questions and answers and labs related to NS0-521 certification exam. These NS0-521 practice exam questions and answers are verified by a team of IT professionals and can help you pass your exam with minimal effort.

    This NS0-521 exam preparation package consists of:

    • A NS0-521 PDF study exam material with 111 practice Questions and Answers.
    • A NS0-521 Interactive Test Engine or VCE with references and explanations for each exam topic.
  • How do I get access to this NS0-521 practice exam package?

    As soon as your payment is done you can get instant access to download the NS0-521 study material.

  • Does the advertised price for this NS0-521 study package include everything?

    Yes, the price is a one time payment and includes all the latest relevant material of the NS0-521 Certification Exam. It also includes the License Key for the Interactive Learning Software.

  • How can this NS0-521 Exam package prepare me to get my NS0-521 certification?

    The content of this NS0-521 study package is created by a team of Network Appliance training experts and it includes up-to-date and relevant Network Appliance NS0-521 material.

  • Can I install the NS0-521 Test Engine Software (Xengine App) on MacOs and Windows?

    Yes, the NS0-521 Test Engine Software is compatible with Windows Operating System and MacOs.

  • Is it safe to buy this Network Appliance NS0-521 Exam Study Package from your website?

    Our site is 100% safe and secure and PCI compliant. As you can see our entire site runs on an ENCRYPTED HTTPS Secure Socket Layer (SSL) protocol. We accept all major credit cards and debit cards.